Skip to content

Shipley et al. (2026): mouse CA1 on an 8-arm radial maze, with rest

The question. Do place cells of an Alzheimer's mouse model hold their map of a radial maze, and is the replay during rest that should stabilize it intact? This dataset is tetrode recordings in CA1 of App NL-G-F/ChAT-cre mice and wild-type littermates over 36 days of a radial-maze memory task, each day with a 45-minute rest recording. It suits place fields on a track graph, comparing them across a day's trials, and decoding position on the maze.

Dataset id shipley_2026
Animal and region Male App NL-G-F/ChAT-cre and wild-type mice, CA1 pyramidal layer
Apparatus 8-arm radial maze, 80 x 10 cm arms on an octagonal centre platform 24.7 cm across; a rest box on the platform
Archive UCL Research Data Repository 30902972 (CC-BY-4.0): one 4.4 GB zip, of which each day reads about 47 to 162 MB by byte range
Sessions 36 days of 14 mice (14 more days of the archive are not offered; see below). One is checked by hand: the default m4005_2020-09-26 (71 units)
from neurospatial.datasets import catalog

sessions = catalog().query("dataset == 'shipley_2026'")
sessions[["session", "n_units", "verified", "default"]].head()
from neurospatial import compute_spatial_rates
from neurospatial.datasets import load

rec = load("shipley_2026")
rates = compute_spatial_rates(
    rec.env,
    rec.spike_times,
    rec.times,
    rec.positions,
    epochs=rec.params["analysis_epochs"],
    min_speed=rec.params["min_speed"],
)

What was recorded

Units from 16 tetrodes in the CA1 pyramidal layer, sorted with Kilosort 2.0 and curated in Phy. On each test day four arms were baited. The day began with an 8-minute exploration trial, then two sessions of five trials (4 minutes at most, or until the mouse had visited the four baited arms), separated by a 45-minute rest recording in a cylindrical box on the centre platform; a 2-minute holding-box interval separated the trials (the paper's Methods). Position is the headstage's LEDs, filmed by an overhead camera at about 30 Hz.

The default day, m4005_2020-09-26, is an App NL-G-F/ChAT-cre mouse: 71 good units, 11 maze trials (0, the exploration, to 10) and one rest recording (S2). Each mouse's genotype is in the record's MouseStats.xlsx and in the summary.

Each day is read from four members of its PhyOutput/OldData folder: spike_times.npy, spike_clusters.npy, cluster_info.tsv and trialData_newMUA.mat.

Units and conversions

What the loader did Basis Evidence
spike times: spike_times.npy / 30 kHz for the clusters cluster_info.tsv labels good stated The Methods' 30 kHz sampling; the spikes must equal the curated spike times the file's tetrodes hold, or the day is refused.
positions: cm = pos.xy (pixels) / pixels_per_metre x 100 stated The file's header: 274 pixels per metre. The camera frame's handedness (whether pixel y grows up or down the room) is not stated, so the positions keep the file's axes and may be the room's mirror image; the arms arm_0 to arm_7 are numbered by angle in that frame.
position times: per trial, a straight line from sample index to the times of the spikes the file maps to each sample inferred The file holds no sample times. On the default day the fitted rates are 30.047 to 30.064 Hz, not the header's 30 Hz, and the largest residual is 41 ms (about one frame). The camera's own timestamps in the zip (experiment_1_pos.npy) agree for the two trials checked.
epochs: exploration (trial 0), trials (the test trials), maze (both) and rest (S1, S2); rec.trials holds the maze trials stated The Methods' day structure and the file's trial names.
environment: a star of eight 80 cm arms from a 24.7 cm platform, 2 cm bins along the track, placed on the maze trials' samples inferred Each arm's direction is the principal axis of its samples, and the centre the point nearest those axes; the Conversion gives how far the axes pass from the centre and how far the samples reach along each arm.
headings none rec.headings is None: the file stores one LED, and pos.dir equals the direction of displacement.

Watch out

  • The clock is the day's recordings joined together. The Methods say the day's recordings were combined for spike sorting, so the 2-minute holding-box intervals are not in the clock: each trial starts within a few frames of the previous one's end. Durations within a trial are real; times between trials are not.
  • Days not offered. The archive holds 50 days of 15 mice; 14 days cannot be put on one increasing clock, so the catalog does not list them (all three days of m4232 among them). The file's map puts each spike at the nearest frame, with each recording's frames timed by a straight line from its first to its last camera timestamp (the experiment_1_pos.npy of each recording folder, which the loader does not read). In 12 days a recording's fitted line starts before the previous one's ends. In 8 the overlap is 0.04 to 0.75 ms: recordings follow each other on this clock with gaps from under 1 ms to about 100 ms (0.2 ms on an offered day), so these are two fitted lines with no gap between them crossing by a fraction of a frame. In the other 4 the earlier recording's camera dropped frames, so its straight line spans more than its place on the spike clock and runs into the next recording: rest S1 in m4201_2019-12-17, m4202_2019-12-16 and m4020_2020-08-18 (overlaps of 0.8 to 10.6 s; S1's camera timestamps hold 35, 25 and 332 gaps over 0.1 s and depart from a straight line by up to 3.8, 2.3 and 8.9 s) and trial 0 in m4604_2022-03-02. In m4020_2020-08-18 the file's own map splits the spikes of 3727.6 to 3738.2 s between S1 and trial 6, interleaved. In 2 days the sorted spikes start late, so a trial has no spikes to time its samples:
Day Why it is not offered
m4005_2020-09-28 Trial 8 starts 0.53 ms before trial 7 ends
m4101_2020-11-03 Trial 2 starts 0.34 ms before trial 1 ends
m4230_2020-12-18 Trial 9 starts 0.42 ms before trial 8 ends
m4230_2020-12-19 Trial 5 starts 0.36 ms before trial 4 ends
m4232_2020-12-17 Trial 2 starts 0.38 ms before trial 1 ends
m4232_2020-12-18 Trial 9 starts 0.11 ms before trial 8 ends
m4232_2020-12-19 Trial 5 starts 0.04 ms before trial 4 ends
m4376_2021-08-16 Trial 9 starts 0.75 ms before trial 8 ends
m4604_2022-03-02 Trial 1 starts 28.95 ms before trial 0 ends; trial 0 is fitted at 30.034 Hz against the trials' 30.051 Hz (dropped frames)
m4201_2019-12-17 Trial 6 starts 796.89 ms before rest S1 ends; S1 is fitted at 30.004 Hz against 30.050 Hz (dropped frames)
m4202_2019-12-16 Trial 6 starts 1381.64 ms before rest S1 ends; S1 is fitted at 30.024 Hz against 30.051 Hz (dropped frames)
m4020_2020-08-18 Trial 6 starts 10583.43 ms before rest S1 ends; S1 is fitted at 29.668 Hz against 30.050 Hz (dropped frames)
m4020_2020-08-21 Trials 0 to 3 have no spikes mapped to them: the good units' first spike is at 818.68 s
m4578_2021-10-18 Trial 0 has no spikes mapped to it: the first spike of any cluster is at 480.77 s
  • Rebuilt position times. Within a trial the times are a straight line: dropped frames, if any, are not located. The summary gives each day's fitted rates and residuals.
  • Recordings slowed by dropped frames. The file's map times each recording's frames by a straight line from its first to its last camera timestamp. Where the camera dropped frames, the line spans more time than the frames left take, so the recording's fitted rate falls below the day's trials'. A recording more than 8 robust standard deviations of the trials' rates below their median gets a watch-out giving that extra time, about how far its positions may be off; the positions are kept. On the offered days this is rest S2 of m4098_2020-10-26 (1.54 s) and of m4202_2019-12-15 (1.04 s), and the exploration trial of m4020_2020-08-19 (5.05 s); the camera's own timestamps depart from the line by 2.0, 0.64 and 4.9 s there. Rates above the median, which dropped frames cannot cause, reach 6.4 robust standard deviations on the offered days. On the six offered days whose camera timestamps were read (these three, the default, m4005_2020-09-24 and m4201_2019-12-16), every other recording's camera times stay within 0.23 s of its line. In the 2021 and 2022 days of some mice every fitted rate is exactly 30 Hz, so the file's map was likely built from the header's rate and the fit cannot measure the camera.
  • No headings. The file stores one LED (n_leds 1), though the Methods fit two, and pos.dir equals dir_disp, the direction of displacement.
  • Processed positions. The authors removed position jumps and interpolated over them (Methods), so held and fast samples describe that processing as much as the tracking. In the default day 20% of samples repeat the one before in runs of 11 or more, most of them during rest.
  • Genotype. Pool days by genotype, not across it; the summary names each mouse's.
  • A missing rest. The default day has one rest recording, S2; the first (S1) is not in the archive.

Analysis choices

rec.params: bin_size 2 cm and min_speed 2 cm/s, the paper's rate-map bins and running-speed filter; analysis_epochs, the maze trials, so rate maps leave out the rest box; train_epochs and test_epochs, the even and odd maze trials, for held-out decoding at dt 0.25 s.

Worked result

Status: not possible yet.

The paper's numbers pool many mice and days (for example the peak firing rates of 232 wild-type and 222 NL-G-F place cells), and its replay results need a replay analysis of the rest recordings; none is a number one day can reproduce.

Cite

Shipley S, Abrate MP, Hayman R, Chan D, Barry C (2026). Disrupted hippocampal replay is associated with reduced offline map stabilization in an Alzheimer's mouse model. Current Biology 36, 859-871.e5. https://doi.org/10.1016/j.cub.2025.12.061

Data: Shipley S, Abrate MP, Hayman R, Chan D, Barry C (2025). Supporting data for: Disrupted hippocampal replay is associated with reduced offline map stabilisation in an Alzheimer's mouse model (Version 1) [Data set]. University College London. https://doi.org/10.5522/04/30902972.v1